TERMINAL DIAGRAM

Control Techniques Unidrive SP AC Drive Terminal Diagram Connections.

NOTE

*

Thermal protection required. Braking Transisto” is not included in Vnidrive HiHP.

For complete instructions, refer to the Unidrive SP Instruction Manual and User Guide available from local supplier or controltechniques.

Programmable Analog
Programmable Digital 
Non-Programmable

TERMINAL DESCRIPTION

Pin#Function*Type/Description Notes
10V Common
2+24VDC External InputBack up Power
Supply for Control
60W, 24 VDC
30V CommonCommon for
External Analog Devices
4+10VDC User SupplyReference Supply10 mA max
5Analog Input 1 (Local
Frequency/Speed
Reference)
Differential Analog Input, Non-inverting Input, 16 bit+10 VDC
100k Ohms
6Analog Input 1 (Local
Frequency/Speed
Reference)
Differential Analog Input, Inverting Input 16 bit+10VDC
100k Ohms
7Analog Input 2 (Remote
Frequency/Speed
Reference)
Single-ended Analog Input 10 bit+10VDC, 100k Ohms or 4-20 mA, 200 Ohms**
8Analog Input 3Single-ended Analog Input 10 bit+10 VDC, 100k Ohms or 4-20 mA, 200 Ohms**
9Analog Output 1 (Frequency/Speed Monitor)Single-ended Analog
Output. BI-polar,
10 bit
+10VDC or
0-20 / 4-20 mA**
10Analog Output 2 (Motor
Torque Monitor)
Single-ended Analog Output, Bi-polar,
10 bit
+10VDC or
0-20 / 4-20 mA**
11OV CommonCommon External
Analog Signals
210V Common
22+24 VDC User OutputUser Supply200 mA max
230V CommonCommon for
External Digital Inputs
24Digital I/O 1
(Zero Speed Output)
Digital Input/Output0 to 24 VOC input, or
1 to 24 VDC, 100 mA
max output
25Digital I/O 2 (Reset Input)
100 mA max output
Digital Input/Output0 to 24 VDC input, or
1 to 24 VDC
26Digital I/O 3
(Run Forward Input)
Digital Input/Output0 to 24 VDC input, or
1 t024VDC, 100 mA
max output
27Digital Input (Run Reverse)Digital Input0 to 24 VDC, 7.5k Ohms
28Digital Input
(Local/Remote)
Digital Input0 to 24 VDC, 7.5k Ohms
29Digital Input (Jog)Digital Input0 to 24 VDC, 7.5k Ohms
300V CommonCommon for External
Digital Inputs
31Digital Input (Secure
Disable)
Digital Input0 to 24 VDC,
1 sec sample
41Status Relay (Drive Heavy)Normally Open240 VAC, 2A resistive
42Status Relay (Drive Heavy)Normally Open240 VAC, 2A resistive
Programmable AnalogProgrammable Digital

All Analog I/O is scalable

* Values In (parenthesIs) designate default functions.
** 0-20, 4-20 mA modes are also available. See Unidrive SP Manual.

Information provided by Control Techniques, a world leader in the design, production and marketing of electronic drives for the control of electric motors.