| Environment |
| IP66 Nema 4X rating for mounting in close proximity to the motor and
application. |
| Ambient temperature 40°C (104°F) without derating. Up to 50°C
operation with a maximum derating of only one motor size. |
| Removable gland plate for easy termination and removal of control and
motor cables. |
| Complies with EN954-1 Cat 3 with PX-Secure option. EMC cable gland option
for shielded cable management. |
| Electromagnetic Immunity complies with EN61800-3 (Drive standard) and
EN61 000-6-2
(generic standard). |
| Electromagnetic Emissions complies with EN61800-3 (Drive standard - 1st
and 2nd
environment) with integral EMC filter. |
Complies with EN61000-6-3 and EN61000-6-4
(Generic standard) with integral
EMC filter. |
| Earth leakage current less than 3mA with integral EMC filter in circuit. |
European Hygienic Engineering and Design Group EHEDG and FDA hygienic recommendations
have been adopted for the food industry
No paint.
Anodised aluminium heat sink.
Polycarbonate covers.
All
slopes> 3 degrees incline
Roughness < 0.8 microns.
No zones where liquids can accumulate. |
|
| Control |
| Open loop vector control. |
| V/F control. |
| Closed loop vector with PX-Encoder option. |
| Speed reference input 0-1 OV, 0-20mA,
4-20mA. |
| Digital inputs Enable, Run forward, Run reverse, Jog, local/remote select |
| Switching
frequency 3kHz to 11 kHz with 4.5kHz as default. |
| Acceleration and Deceleration ramps (linear and S-type). |
Serial communication as standard
| Modbus RTU RS485 via RJ45 connector. |
|
DC injection braking as standard.
Integral dynamic braking transistor
and resistor PID Controller. |
| Protection |
| Undervoltage, Supply and DC Link overvoltage, Phase loss, Drive overload,
Instantaneous overcurrent, Over temp, Short circuit, Ground fault, Over
heat, Motor thermal,
Watchdog. |