Call Toll Free (866) 492-9888
|
ABB ACS800 AC DRIVES
0.5 to 100Hp @ 208 to 240V
1.5 to 600Hp @ 380 to 500V
460V Ratings
3-phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V - Power ratings are valid
at nominal voltage, 480V (60Hz power line)
Type Code
NEMA 1 (6,7) |
I max
A (3) |
Nominal Ratings (4, 5) |
Frame
Size |
Price |
Normal Duty
(VT) (1)
(110% I2N) |
Heavy-duty (CT) (2)
(150% I2hd) |
I 2N
A |
P N
HP (8) |
I 2hd
A |
P hd
HP (8) |
| Wall
Mounted Drives |
| ACS800-U1-0004-5 |
6.5 |
4.9 |
3 |
3.4 |
2 |
R2 |
$999.00 |
| ACS800-U1-0005-5 |
8.2 |
6.2 |
3 |
4.2 |
2 |
R2 |
$1,179.00 |
| ACS800-U1-0006-5 |
10.8 |
8.1 |
5 |
5.6 |
3 |
R2 |
$1,179.00 |
| ACS800-U1-0009-5 |
13.8 |
11 |
7.5 |
8.1 |
5 |
R2 |
$1,388.00 |
| ACS800-U1-0011-5 |
17.6 |
14 |
10 |
11 |
7.5 |
R2 |
$1,543.00 |
| ACS800-U1-0016-5 |
24 |
21 |
15 |
15 |
10 |
R3 |
$1,892.00 |
| ACS800-U1-0020-5 |
32 |
27 |
20 |
21 |
15 |
R3 |
$2,278.00 |
| ACS800-U1-0025-5 |
46 |
34 |
25 |
27 |
20 |
R3 |
$2,839.00 |
|
ACS800-U1-0030-5 |
62 |
42 |
30 |
34 |
25 |
R4 |
$3,422.00 |
| ACS800-U1-0040-5 |
72 |
52 |
40 |
37 |
30(3) |
R4 |
$4,079.00 |
| ACS800-U1-0050-5 |
86 |
65 |
50 |
52 |
40 |
R5 |
$4,865.00 |
| ACS800-U1-0060-5 |
112 |
79 |
60 |
65 |
50 |
R5 |
$5,595.00 |
| ACS800-U1-0070-5 |
138 |
96 |
75 |
77 |
60 |
R5 |
$6,331.00 |
| ACS800-U1-0100-5 |
164 |
124 |
100 |
96 |
75 |
R6 |
$7,429.00 |
| ACS800-U1-0120-5 |
202 |
157 |
125 |
124 |
100 |
R6 |
$8,598.00 |
| ACS800-U1-0140-5 |
282 |
180 |
150 |
156 |
125 |
R6 |
$9,825.00 |
| Free Standing
Drives w/Enclosure Extensions |
| ACS800-U2-0170-5 |
326 |
192 |
150 |
162 |
125 |
R7 |
$15,437.00 |
| ACS800-U2-0210-5 |
384 |
240 |
200 |
192 |
150 |
R7 |
$17,850.00 |
| ACS800-U2-0260-5 |
432 |
289 (4) |
250(3) |
224 |
150 |
R7 |
$21,229.00 |
| ACS800-U2-0300-5 |
568 |
361 |
300 |
302 |
250 |
R8 |
$24,636.00 |
|
ACS800-U2-0320-5 |
588 |
435 |
350 |
340 |
250 |
R8 |
$28,592.00 |
| ACS800-U2-0400-5 |
588 |
510 |
400 |
370 |
300 |
R8 |
$32,586.00 |
| ACS800-U2-0440-5 |
840 |
545 |
450 |
490 |
400 |
R8 |
$36,775.00 |
| ACS800-U2-0490-5 |
840 |
590 |
500 |
515(5) |
450 |
R8 |
$40,922.00 |
| ACS800-U2-0550-5 |
1017 |
670 |
550 |
590(5) |
500 |
R8 |
$45,476.00 |
|
ACS800-U2-0610-5 |
1017 |
704(4) |
600 |
590(5) |
500 |
R8 |
$49,714.00 |
| Cabinet
Drives |
| ACS800-U7-0100-5 |
164 |
124 |
100 |
96 |
75 |
R6 |
$9,919.00 |
| ACS800-U7-0120-5 |
202 |
157 |
125 |
124 |
100 |
R6 |
$12,060.00 |
| ACS800-U7-0140-5 |
282 |
180 |
150 |
156 |
125 |
R6 |
$13,984.00 |
| ACS800-U7-0170-5 |
326 |
192 |
150 |
162 |
125 |
R7 |
$14,607.00 |
| ACS800-U7-0210-5 |
384 |
240 |
200 |
192 |
150 |
R7 |
$17,281.00 |
| ACS800-U7-0260-5 |
432 |
289(4) |
250(3) |
224 |
150 |
R7 |
$20,981.00 |
| ACS800-U7-0270-5 |
480 |
316 |
250 |
240 |
200 |
R8 |
$20,981.00 |
| ACS800-U7-0300-5 |
568 |
361 |
300 |
302 |
250 |
R8 |
$24,109.00 |
| ACS800-U7-0320-5 |
588 |
435 |
350 |
340 |
250 |
R8 |
$28,420.00 |
| ACS800-U7-0400-5 |
588 |
510 |
400 |
370 |
300 |
R8 |
$31,823.00 |
| ACS800-U7-0440-5 |
840 |
545 |
450 |
490 |
400 |
R8 |
$35,719.00 |
| ACS800-U7-0490-5 |
840 |
590 |
500 |
515(5) |
450 |
R8 |
$39,528.00 |
| ACS800-U7-0550-5 |
1017 |
670 |
550 |
590(5) |
500 |
R8 |
$44,732.00 |
| ACS800-U7-0610-5 |
1017 |
718(4) |
600 |
590(5) |
500 |
R8 |
$49,303.00 |
 |
| ACS800-07-0760-5* |
1321 |
848 |
700 |
660 |
550 |
1D4+2R8i |
$54,920.00 |
| ACS800-07-0910-5* |
1524 |
1008 |
900 |
785 |
700 |
2D4+2R8i |
$74,246.00 |
| ACS800-07-1090-5* |
1882 |
1208 |
1000 |
941 |
800 |
2D4+2R8i |
$87,601.00 |
|
ACS800-07-1210-5* |
1991 |
1317 |
1150 |
1026 |
900 |
2D4+2R8i |
$104,486.00 |
| ACS800-07-1540-5* |
2655 |
1704 |
1500 |
1328 |
1150 |
2D4+3R8i |
$140,925.00 |
|
ACS800-07-1820-5* |
2956 |
1956 |
1750 |
1524 |
1250 |
2D4+3R8i |
$167,946.00 |
|
ACS800-07-2310-5* |
3901 |
2563 |
2250 |
1997 |
1750 |
3D4+4R8i |
$215,772.00 |
|
* All -07 require plus codes +C129 +F251 +H351 +H353 +H359 for
the included options listed in Hardware Selection & Description at no
additional charge
General and specifically identified notes are at the beginning of the product
selection (ratings) tables
|
|
(Prices good thru February 2012) |
NOTES
- I2N: continuous base current at 40°C (104°F). Overload cycle 110%
I2N for 1
minute / 5 minutes allowed at 40°C (104°F), typical.
- I2hd: continuous base current at 40°C (104°F). Overload cycle 150%
I2hd for 1 minute /100% 5
minutes allowed at 40°C (104°F).
- Imax: current available for 10 seconds at start.
- Current ratings do not change with different supply voltages.
- The rated current of the ACS 800 must be greater than or equal to the rated
motor current to achieve the rated motor power given in the table.
- All -U1 models -0004 through -0140 come with a conduit box as standard.
- All -U2 models -0170 through -0610 come with an extended enclosure. Top entry
/ top exit, US conduit plate, fused disconnect and common mode
filter for drives -0270 and larger. All 02 models come standard with US conduit plate and
bottom entry / bottom exit.
- Horsepower rating is based upon NEMA ratings for most 2,4 and 6-pole motors
(3600, 1800, 1200 rpm). Check motor nameplate current for compatibility.
- Rating not applicable for all motors. Available for some 4-pole 460V high
efficiency NEMA motors.
- With an ambient temperature of 30°C or less, the drive's I2N rating is 289
amps. With a 40°C ambient temperature. maximum I2N is 284 amps.
- 140% I2hd overload current for 1 minute / 5 minutes if the ambient temperature
is 40°C. 150% I2hd overload current for 1 minute
/ 5 minutes @ 30°C.
- With an ambient temperature of 30°C or less, the drive's I2N
rating is 718 amps.
© 2004 ABB Inc. All rights reserved Specification and pricing subject to change without
notice.
ACS800-US-03
Rev. B |
Effective: 06/11/03
Supersedes: 10/07/02 |
|