ABB ACS800 AC DRIVES

0.5 to 100Hp @ 208 to 240V
1.5 to 600Hp @ 380 to 500V

230V Ratings
3-phase supply voltage 200,208 or 230 V – Power ratings are valid at nominal voltage, 230V (50 and 60Hz power lines)

Type Code
NEMA 1 (6,7)
I max
A (3)

Nominal Ratings (4, 5)

Frame
Size
Price
Normal Duty (VT) (1)
(110% I2N)
Heavy-duty (CT) (2)
(150% I2hd)
I 2N
A
P N
HP (7)
I 2hd
A
P hd
HP (7)
Wall Mounted Drives
ACS800-U1-0001-2+P9016.54.913.50.75R2CALL
ACS800-U1-0002-2+P9018.26.61.54.61R2CALL
ACS800-U1-0003-2+P90110.88.126.61.5R2CALL
ACS800-U1-0004-2+P90113.81137.52R2CALL
ACS800-U1-0006-2+P90124215133R3CALL
ACS800-U1-0009-2+P90132277.5175R3CALL
ACS800-U1-0011-2+P901463410257.5R3CALL
ACS800-U1-0016-2+P9016242153110R4CALL
ACS800-U1-0020-2+P9017254204215R4CALL
ACS800-U1-0025-2+P9018669255420R5CALL
ACS800-U1-0030-2+P90111280306825R5CALL
ACS800-U1-0040-2+P901138104408030R5CALL
ACS800-U1-0050-2+P9011641325010440R6CALL
ACS800-U1-0060-2+P9012021576013050R6CALL
ACS800-U1-0070-2+P9012821927515460R6CALL
Free Standing Drives w/Enclosure Extensions
ACS800-U2-0080-2+P9013262117517060R7CALL
ACS800-U2-0100-2+P90140424810020275R7CALL
ACS800-U2-0120-2+P901432290100240(4)75R7CALL
ACS800-U2-0140-2+P901588396150316125R8CALL
ACS800-U2-0170-2+P901588440150340125R8CALL
ACS800-U2-0210-2+P901588516200370150R8CALL
ACS800-U2-0230-2+P901840598200480200R8CALL
ACS800-U2-0260-2+P9011017679250590(5)200R8CALL
ACS800-U2-0300-2+P9011017704250635(5)250R8CALL
Note: All drives are supplied w/Operator Control Panel.

For your specific application contact us for pricing.

NOTES

  1. I2N: continuous base current at 40°C (104°F). Overload cycle 110% I2N for 1 minute / 5 minutes allowed at 40°C (104°F) typical.
  2. I2hd: continuous base current at 40°C (104°F). Overload cycle 150% I2hd for 1 minute / 5 minutes allowed at 40°C (104°F).
  3. 1max: current available for 10 seconds at start.
  4. Current ratings do not change with different supply voltages.
  5. The rated current of the ACS 800 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
  6. All -U1 models -0001 through -0070 come with a conduit box as standard.
  7. Horsepower is based on NEMA motor ratings for most 2,4 and 6-pole motors (3600, 1800, 1200 rpm). Check motor nameplate current for compatibility.

Contact Joliet Technologies for Custom Drive Pricing.
Phone: (815) 725-9696 or
Toll Free: (866) 492-9888
Fax: (815) 725-9393
E-mail: info@joliettech.com
RFQ – Request for Quote

© 2004 ABB Inc. All rights reserved Specification and pricing subject to change without notice.

ACS800-US-03
Rev. B

Effective: 06/11/03
Supersedes: 10/07/02

Print Friendly