ABB ACS800 AC DRIVES
0.5 to 100Hp @ 208 to 240V
1.5 to 600Hp @ 380 to 500V
380V Ratings
3-phase supply voltage 380, 400, 415, 440, 460, 480 or 500 V - Power ratings are valid
at nominal voltage, 400 V (50Hz
power line)
Type Code
NEMA 1 (6,7) |
I max
A (3) |
Nominal Ratings (4, 5) |
Frame
Size |
Price |
Normal Duty
(VT) (1)
(110% I2N) |
Heavy-duty (CT) (2)
(150% I2hd) |
I 2N
A |
P N
kW (8) |
I 2hd
A |
P hd
kW (8) |
| Wall
Mounted Drives |
|
ACS800-U1-0004-5 |
6.5 |
4.5 |
1.5 |
3.4 |
1.1 |
R2 |
CALL |
| ACS800-U1-0005-5 |
8.2 |
5.6 |
2.2 |
4.2 |
1.5 |
R2 |
CALL |
| ACS800-U1-0006-5 |
10.8 |
7.7 |
3 |
5.6 |
2.2 |
R2 |
CALL |
| ACS800-U1-0009-5 |
13.8 |
10 |
4 |
7.5 |
3 |
R2 |
CALL |
|
ACS800-U1-0011-5 |
17.6 |
12 |
5.5 |
9.2 |
4 |
R2 |
CALL |
| ACS800-U1-0016-5 |
24 |
18 |
8 |
13 |
6 |
R3 |
CALL |
| ACS800-U1-0020-5 |
32 |
23 |
11 |
18 |
8 |
R3 |
CALL |
| ACS800-U1-0025-5 |
46 |
31 |
15 |
23 |
11 |
R3 |
CALL |
| ACS800-U1-0030-5 |
62 |
39 |
18.5 |
32 |
15 |
R4 |
CALL |
| ACS800-U1-0040-5 |
72 |
44 |
22 |
36 |
18.5 |
R4 |
CALL |
| ACS800-U1-0050-5 |
86 |
61 |
30 |
50 |
22 |
R5 |
CALL |
| ACS800-U1-0060-5 |
112 |
75 |
37 |
60 |
30 |
R5 |
CALL |
| ACS800-U1-0070-5 |
138 |
88 |
45 |
69 |
37 |
R5 |
CALL |
|
ACS800-U1-0100-5 |
164 |
115 |
55 |
88 |
45 |
R6 |
CALL |
| ACS800-U1-0120-5 |
202 |
145 |
75 |
113 |
55 |
R6 |
CALL |
| ACS800-U1-0140-5 |
282 |
163 |
90 |
141 |
75 |
R6 |
CALL |
| Free Standing
Drives |
| ACS800-02-0170-5+P901 +H358 |
326 |
192 |
90 |
162 |
90 |
R7 |
CALL |
|
ACS800-02-0210-5+P901 +H358 |
404 |
240 |
132 |
192 |
90 |
R7 |
CALL |
| ACS800-02-0260-5+P901 +H358 |
432 |
284 |
160 |
224 |
110 |
R7 |
CALL |
ACS800-02-0320-5+P901
+E208+H358 |
568 |
361 |
200 |
284 |
160 |
R8 |
CALL |
| ACS800-02-0400-5+P901 +E208+H358 |
720 |
477 |
250 |
361 |
200 |
R8 |
CALL |
| ACS800-02-0440-5+P901 +E208+H358 |
904 |
515 |
250 |
477 |
250 |
R8 |
CALL |
|
ACS800-02-0490-5+P901 +E208+H358 |
1017 |
590 |
315 |
515 (10) |
250 |
R8 |
CALL |
| ACS800-02-0550-5+P901 +E208+H358 |
1017 |
632 |
355 |
590 (10) |
315 |
R8 |
CALL |
| ACS800-02-0610-5+P901 +E208+H358 |
1017 |
704 |
400 |
590 (10) |
315 |
R8 |
CALL |
| Free Standing
Drives w/Extension Enclosure |
| ACS800-02-0170-5+C111 +P901 +H358 |
326 |
192 |
90 |
162 |
90 |
R7 |
CALL |
| ACS800-02-0210-5+C111 +P901 +H358 |
404 |
240 |
132 |
192 |
90 |
R7 |
CALL |
| ACS800-02-0260-5+C111 +P901 +H358 |
432 |
284 |
160 |
224 |
110 |
R7 |
CALL |
| ACS800-02-0320-5+C111 +P901 +E208+H358 |
568 |
361 |
200 |
284 |
160 |
R8 |
CALL |
|
ACS800-02-0400-5+C111 +P901 +E208+H358 |
720 |
477 |
250 |
361 |
200 |
R8 |
CALL |
| ACS800-02-0440-5+C111 +P901 +E208+H358 |
904 |
515 |
250 |
477 |
250 |
R8 |
CALL |
|
ACS800-02-0490-5+C111 +P901 +E208+H358 |
1017 |
590 |
315 |
515 (10) |
250 |
R8 |
CALL |
| ACS800-02-0550-5+C111 +P901 +E208+H358 |
1017 |
632 |
355 |
590 (10) |
315 |
R8 |
CALL |
|
ACS800-02-0610-5+C111 +P901 +E208+H358 |
1017 |
704 |
400 |
590 (10) |
315 |
R8 |
CALL |
|
Note: All drives are supplied w/Operator Control Panel. |
|
(Call Joliet Technologies for
prices) |
NOTES
- I2N: continuous base current at 40°C (104°F). Overload cycle 110%
I2N for 1
minute / 5 minutes allowed at 40°C (104°F).
- I2hd: continuous base current at 40°C (104°F). Overload cycle 150%
I2hd for 1
minute / 100% 5 minutes allowed at 40°C (104°F).
- 1max: current available for 10 seconds at start.
- Current ratings do not change with different supply voltages.
-
The rated current of the ACS 800 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
-
All -U1 models -0004 through -0140 come with a conduit box as standard.
- All-02 models -0170 through -0610 with added option codes come with bottom
entry I exit, US conduit plate (H358) and common mode filters (E208) for drives
-0320 and larger. The extended enclosure (C111) adds a fusible disconnect with
power cabie entry and exit remaining bottom / bottom. If European conduit plate
is desired, delete option H358 with no price change.
-
Kilowatt rating is based upon IEC ratings for most 2,4 and 6-pole motors (3000, 1500, 1000 rpm). Check motor nameplate current for compatibility.
- When ordering 380V IP54 R6 units, order as ACS800-01-xxxx-5+B056+H358 (NOTE: This unit will NOT ship
w/ a UL label).
- 140% I2hd overload current for 1 minute
/ 5 minutes if the ambient temperature
is 40°C. 150% I2hd overload current for 1 minute
/ 5 minutes @ 30°C.
© 2004 ABB Inc. All rights reserved Specification and pricing subject to change without
notice.
ACS800-US-03
Rev. B |
Effective: 06/11/03
Supersedes: 10/07/02 |
|