Call Toll Free (866) 492-9888
|
Joliet Technologies is proud to be an integrator of Soft Starter
Products by SOLCON.
HRVS-DN
Digital Soft Starter with Advanced Protection for High and Medium Voltage
Digital soft starter for high and medium voltage motors. Incorporates features
similar to those of the RVS-DN. Range: 60-2500A, 100-25000KW, 1500-15000V,
(Consult Factory for 1500-1800A, 13800-15000V). The HRVS-DN digital soft starter
comes in a variety of versions. It features integrated motor insulation protection
and has many additional features which can be tailored to suit your needs.
Medium Voltage Digital Soft Starter 30-2700A, 1500-15000V
This advanced, micro-processor controlled through fiber optic links, Medium
Voltage soft starter is designed for use with standard asynchronous and synchronous
motors.
The HRVS-DN is a highly sophisticated digital soft starter which ensures smooth,
stepless acceleration and deceleration, eliminating current and mechanical
shocks to the motor and load.
Medium Voltage Soft-Starter,
for Asynchronous and Synchronous Motors 50-2700A, 1500-15000V
Static & Rotating Exciters
Static: 60-240Vdc, 40-1000A
Rotating: Any Range
Incorporating microprocessor circuitry with fiber optic control, the HRVS-DN
is the ideal soft-starting solution for medium voltage asynchronous as well
as synchronous motors.The sophisticated control ensures superior acceleration
and deceleration, thus, eliminating current and mechanical shocks.
The starter can be supplied as Chassis (IP00) or Enclosed (IP31-67, NEMA 1-6X)
with options such as Line and Bypass vacuum contactors or circuit breakers,
disconnect switches, main and control protection fuses, motor protection relay,
etc.
HRVS-DN
MEDIUM VOLTAGE SOFT STARTER, DIGITAL for MOTORS 30-2700A, 1500-15000V
Medium Voltage Soft Starter Integrated Motor Insulation Protection
Introduction
The HRVS-DN is a third generation, digital Medium Voltage, Soft Starter,
designed for use with standard MV asynchronous and synchronous motors.
This highly sophisticated soft starter ensures smooth, step-less acceleration
and deceleration, eliminating high inrush current and damaging mechanical
torque on startup and mechanical wear on stopping. The HRVS-DN is available
as a stand-alone product or as part of a complete system including Line
and/or Bypass Contactors. Additional options for medium voltage soft starter
include Load Break Switch, Motor Protection Relay, Digital Multimeter,
etc.
We can customise our medium voltage soft starters to solve all of your
inrush and starup problems. To see what we can do for you sign up now to
become a distributor.
Advantages at a Glance for the HRVS-DN Medium Voltage Soft Starter
- Eliminates high inrush current and high mechanical torque on startup.
- Soft, stepless acceleration & deceleration.
- Unique starting & stopping characteristics.
- User friendly, straight forward set-up and operation.
- Sophisticated motor protection package.
- Heavy duty design: 50°C ambient temperature.
- Innovative low voltage test mode - full function-testing with a
small L.V motor, using LV mains.
- Advanced Electronic Potential Transformer utilizing Patent
Pending "wireless" fiber-optic
controlled firing system.
- Each starter is tested for Partial Discharge (corona) to
ensure long term reliability.
- Power factor capacitors can be connected directly to
the upstream contactor.
- IP30-standard, higher protection by special order.
- Two optional methods of delivery: Chassis type for
self assembly or Complete system
- RS485 Communication with MODBUS, PROFIBUS or MODBUS/TCP
protocols (others available on request)
- Wide 45-65Hz Auto-tracking frequency range realized
by special software with unique hardware arrangement.
(designed for Marine, Offshore and Generators
operating under continuous frequency fluctuation)
- Torque and current starting and stopping characteristics.
- Pump control software.
- Analog output option.
- Motor Insulation Protection option (with programmable
alarm and trip levels via seperate additional
output).
Medium Voltage Soft Starter Range: 2300-7200V, 30-2700A
Medium Voltage Soft Starter Range: 10000-13800V, 30-2700A
Medium Voltage Soft Starter Range: 13800-15000V, 30-2700A
Approvals of our products and Medium Voltage Soft Starters
Some of the approval bureau's we work with :
as well as : BV, RINA
Starting & Stopping
- Soft start and soft stop
- Current limit
- Torque & Current Control ramps
- Pump Control characteristics
- Pulse (kick) start
- Tacho/encoder feedback (option)
- Dual Adjust - 2 start/stop characteristics for varying loads, two
speed motors, etc.
Soft starting and stopping utilizing our world renown "Pump Control
Program"- choose the most effective curve for acceleration, deceleration
and adjust for final torque.
Set-up & Supervision of a Medium Voltage Soft Starter
- Illuminated LCD with 2 lines, 16 characters each.
- Selectable languages: English, German, French or Spanish.
- The LCD displays motor current, fault description as well as statistical
data.
- Easy set-up using six soft-touch keys to change preprogrammed default
parameters.
- Eight LEDs for a quick status display:
-
Control voltage On & Self Test OK
- Motor soft starting
- Motor running
- Motor soft stopping
- Motor stopped
- Test Mode Activated
- Dual Adjust mode
- Fault
Statistics
- Last Starting Period
- Last Start Maximum Current
- Total Run Time
- Number of Starts
- Last Trip
- Trip Current
- Total Number of Trips
- Historical Trip Event Recorder (10 Event conditions)
Control Inputs & Outputs for a Medium Voltage Soft
Starter
- Control voltage: 110-120, 220-240VAC / 50-60Hz or 110 - 220VDC to
be specified at time of order.
- Separate inputs for Start, Stop (Emergency) and Soft Stop.
- Two programmable External fault inputs - will stop the motor 2 sec.
after the contact closes
- Aux. Contacts - three C/O relays, 8A, 250V, 2000VA (four C/O
relays when Insulation option is used) :
- Immediate Relay - changes position upon start signal, with
adjustable On & Off
delays.
Returns to original position upon Voltage Outage, Fault, Stop signal
and Soft stop signal.
at the end of soft stopping process. It can also be configured
as a "Shear-pin
Alarm" contact.
- End of Acceleration Relay - operates upon completion
of starting process, with adjustable
On delay. Returns to original position upon Voltage outage,
Fault, Stop and Soft Stop signals.
- Fault Relay - can be programmed as:
Fault - changes position upon Fault, returns to original
position upon Reset.
Fault-Fail-Safe - changes position upon control voltage
connection, returns upon fault.
- Insulation Alarm relay - changes position upon
insulation detection at a pre-programmed level.
Typical Applications for a Medium Voltage Soft Starter
Fans and centrifuges
- Conveyors and monorail systems
- Pumps, Compressors and Chillers
- Starting large motors from weak power supply
(diesel generators, long supply lines, etc.)
Marine & Offshore Applications for a Medium Voltage Soft Starter
Thrusters
- Cargo Pumps (LNG, LPG, etc.)
- Water & Ballast pumps
- Refrigeration compressors
- Hydraulic pumps & power packs
- Main Propulsion (Variable Pitch Propellers)
Northern Swan, soft starting 8 cargo pumps and 2 compressors.
Courtesy: Woodside
Comprehensive Motor & Starter
Protection
with Occurrence status table |
Active During |
Start |
Run |
Stop |
Soft Stop |
| Too many starts & Start Inhibit Time |
X |
|
|
|
| Electronic Overload with selectable curves |
|
X |
|
|
| Shear Pin (Jam) |
Starter Protection - trip function at 850% FLC in less
than 1 cycle
|
X |
|
X |
X |
| Motor Protection - trip function |
During Start-factory set at 850% FLA in less than 1 cycle
|
X |
|
|
X |
During Run-adjustment 200-850% FLA with adjustable delay
|
|
X |
|
|
| Programmable setting |
Starter Protection - trip function at 850% FLC
|
X |
X |
|
X |
Motor Protection - Alarm & Trip
functions
On fault "Immediate Relay" acts as alarm w/adjustable delay.
Trip will not occur if fault is cleared within the time delay. |
During Start - preset at 850% FLA with adjustable delay
|
X |
|
|
X |
During Run - prog. 200-850% FLA with adjustable delay
|
|
X |
|
|
| Under current |
|
X |
|
|
| Unbalance Current |
X |
X |
|
X |
| Ground Fault Current |
|
X |
|
|
| Phase loss |
X |
X |
|
X |
| Phase sequence |
X |
X |
|
X |
| Under voltage. Time delay is overridden in a "No-Volt" case |
X |
X |
|
X |
| Over voltage with adjustable time delay |
X |
X |
|
X |
| Under / Over Frequency when range exceeds "Auto Tracking" |
X |
X |
|
X |
| Long start time (Stall protection) |
X |
|
|
|
| Shorted SCR & Wrong connection (Load Loss) |
X |
|
|
X |
| External fault 1 & 2 |
X |
X |
X |
X |
| SCR protection by Metal Oxide Varistors (MOV) |
X |
X |
X |
X |
| Starter over-temperature |
X |
X |
X |
X |
Starter internal test Passed
When supply voltage is connected and after the "On" LED is lit. |
X |
X |
X |
X |
| Power ON & NO Start signal |
|
|
X |
|
| By-Pass contactor Open |
|
X |
|
|
Scope of supply
Chassis type or Cabinet (IP 30-54) or NEMA,with L.V. & M.V. segregated
compartments.
Single or Multi-Motor Versions.
Single : One Soft-Starter and One Motor
Multi : One Soft-Starter and
Two to Four Motors
- HRVS-DN M.V. soft starter
- Line & Bypass Vacuum Contactors
- Low voltage control system
Options for a Medium Voltage Soft Starter
- Insulation Alarm - where motor insulation is continuously
checked. Alarm and Trip levels are programmable
- Communication:
RS 485 with MODBUS, PROFIBUS or MODBUS-TCP
- Analogue Output
of motor current
(field programmable 0-10VDC, 0/4-20mA or inverse)
- Motor Protection
Relay MPR 2000 with up to 10 temperature inputs (Thermistors /
RTDs) consult factory for further details
- Main Isolator
including handle, Motor Protection type main fuses (with or without blown
fuse indicator) etc (Incoming Cabinet containing
all the options)
- Digital Power, Voltage and Current Meter DPM-10, for continuous
parameter display.
soft starter, soft starters, Medium Voltage soft-starter, Medium Voltage
soft-starters, Medium Voltage soft starter, Medium Voltage soft starters,
arrancador media tension, media tension partidor. Marine duty medium voltage
soft starter. HRVS-DN Ex for mining applications.
|