SIMOREG 6RA70 Siemens DC Master Variable Speed DC Drive
Description & Base Drive Catalog Numbers
- Description &
Base Drive Catalog Numbers
- Features
- Design and Mode of Operation
Description
Base Drive Description
Series 6RA70 SIMOREG DC MASTER base drive converters are complete drive assemblies ready to be
installed and operated. They include a 3-phase armature converter, single-phase field converter, main
contactor, protective semiconductor fuses, control power transformer, and power / control terminals.
Base drive converters are fully digital, compact units which supply the armature and
field of variable speed DC drives with rated armature currents from 15A to 1660A. The
motor field circuit can be supplied with DC currents of up to 40A (current levels depend
on the armature rated current).
General Information
Series 6RA70 SIMOREG DC MASTER converters are characterized by their compact,
space-saving construction. Their compact design makes them particularly easy to
service and maintain since individual components are readily accessible. The electronics box contains the basic electronic circuitry as well as
any supplementary option boards.
All SIMOREG DC MASTER units are equipped with a PMU simple operator panel mounted in the converter
door. The panel consists of a five-digit, seven-segment display, three LED's as status indicators and three
parameterization keys. The PMU also features connector X300 with an USS interface in accordance with
the RS232 or RS485 standard. The panel provides all the facilities for making adjustments or settings and
displaying measured values required to start-up the converter.
The OP1 S optional converter operator panel can be mounted directly in the converter
door or externally, e.g., in the cubicle door. When mounted remotely, the OP1 S can be
connected to the converter with cables up to 5 meters (15 feet) length. Cable up to 200
meter (600 feet) in length can be used if a separate 5 VDC power supply is available.
The OP1 S connects to the SIMOREG through connector X300 using the RS485 interface. The OP1 S can be installed as an economic alternative to conventional door
mounted metering devices (Le., voltmeters, ammeters, and speed indicator).
The OP1 S features a liquid crystal display with 4 x 16 characters for displaying parameter
names in plain text. English, German, French, Spanish and Italian can be selected as
the display languages. In addition the OP1 S can store parameter sets for easy
downloading to other drives.
The converter can also be parameterized on a standard PC with appropriate software connected to the
serial interface on the basic unit. This PC interface is used during start-up, for maintenance during
shutdown and for diagnosis in operation. Furthermore, converter software upgrades can be loaded through
this interface for storage in flash memory.
On single-quadrant converters, a fully controlled three-phase bridge supplies the
armature. On four-quadrant converters, two fully controlled three-phase bridges are
connected in an inverse-parallel connection to allow both positive and negative
armature current. For the field converter, a single-phase, half-controlled 2-pulse bridge
supplies the motor shunt field.
The armature and field converters can operate with AC line frequencies from 45 to 65
Hz. If required for a specific application, the frequency of the armature and field AC
supplies can be different. The armature converter 3 phase AC supply is phase insensitive however on base drives rated 1180 and 1660 amperes,
the 3 phase cooling fan must be connected to get the proper direction of rotation. The power section
cooling system is monitored by means of temperature sensors.
The power section for the armature and field converters is constructed of isolated
thyristor modules for converters rated from 15A to 850A at 460V AG-line voltage. The
heat sink in this case is electrically isolated and at ground potential. On converters
rated 1180 and 1660 amperes at 460 VAC, the power section for the armature circuit is
constructed using disk thyristors and the heat sinks are at line voltage potential. The
housing and terminal covers on power connections provide protection against accidental
contact for operators working in the vicinity. All connecting terminals are accessible
from the front.
All open and closed-loop drive control and communication functions are performed by
two powerful microprocessors. Drive control functions are implemented in the software
as program modules that can be "wired up" and changed by parameters.
Rated DC Current:
The rating plate of the converter module has 3 rated currents listed on it. The first two
are IEG ratings and have no bearing on the base drive rating. The third rating is the US
(NEMA) rating which the base drive rating is derived from.
The US (NEMA) rated current allows operation at rated current followed by an overload
of 150% for 60 seconds in a 45°G ambient. The overload can be applied no sooner than
every 10 minutes. Base drives are designed using the US rating which means that
fuses, contactors, and terminal blocks are sized for the rated US (NEMA) current.
The IEG class I rating is the maximum current the power module can supply continuously with no overload.
Because an overload is not possible the class I rated current is higher than the US rating. The
IEG class I rating cannot be used with base drives because the base drive fuses, contactors, and terminal blocks will
be overloaded.
The microprocessor calculates the current 12t value of the power section cyclically to
ensure that the thyristors are not damaged in overload operation.
Base Drive Catalog Numbers
US RATING
(Amps DC) |
1-QUAD TYPE
(Catalog No.) |
4-QUAD TYPE
(Catalog No.) |
| 15 |
6RA7013-2FS22-0 |
6RA7013-2FV62-0 |
| 30 |
6RA7018-2FS22-0 |
6RA7018-2FV62-0 |
| 60 |
6RA7025-2FS22-0 |
6RA7025-2FV62-0 |
| 100 |
6RA7030-2FS22-0 |
6RA7030-2FV62-0 |
| 140 |
6RA7072-2FS22-0 |
6RA7072-2FV62-0 |
| 210 |
6RA7075-2FS22-0 |
6RA7075-2FV62-0 |
| 255 |
6RA7077-2FS22-0 |
6RA7077-2FV62-0 |
| 430 |
6RA7082-2FS22-0 |
6RA7082-2FV62-0 |
| 510 |
6RA7083-2FS22-0 |
6RA7083-2FV62-0 |
| 850 |
6RA7087-2FS22-0 |
6RA7087-2FV62-0 |
| 1180 |
6RA7091-2FS22-0 |
6RA7091-2FV62-0 |
| 1660 |
6RA7094-2FS22-0 |
6RA7094-2FV62-0 |
Siemens Energy & Automation