MOTORTRONICS
VMX Series
Compact Low Voltage
Soft Start Starters
Ratings from 18A to 1250A
(up to 1200Hp)
240VAC and 480VAC
|
Integrated bypass contactor
Advanced motor protection
Narrow-width for MCC mounting
Low-profile for use in pump panels
Remote keypad mounting
Unique built-in features
|
VMX Series System Protection
World-class motor & system protection...
in a soft starter that is easy to install, easy to wire
& easy to use

Motor Thermal Model
|
Separate Start & Run Overload Protection
Two programmable overload trip
100%. curves allow for the thermal capacity required to start the load,
while providing more closely matched overload protection during the
run time. Real-Time Thermal Modeling
A dynamic thermal register continuously calculates
motor operating temperature even when your motor is not running. Knows when
the motor is cool enough for a successful restart.
Retentive Thermal Memory
Remembers the motor thermal condition even in the
event of a power loss or blackout. Extrapolates motor temperatures using
a real-time clock.
Dynamic Reset Capacity
Overload will not reset until thermal capacity in
the motor is sufficient for a successful restart. Starter learns and retains
this information from previous starts.
Duty Cycle Protection

- Back-spin timer ensures coast-down before restart
- Minimum time between starts lock-out
- Starts-per-hour lockout to prevent motor damage
Equipment ground fault trip and monitoring (residual
current method)
PTC thermistor input for use on motors with embedded
PTC temperature sensors
Current imbalance trip and biasing of the thermal
register
Phase
loss protection based on current and voltage
Electronic
shear pin trip (overcurrent) with trip delay
Load
loss trip (under current) with trip delay
Phase
rotation protection
Pre-start
shorted load protection checks for motor lead or winding
damage
Running
short circuit trip acts like a high speed "electronic
fuse"
Shorted
SCR lockout, defeatable for "must run" situations
Bypass
discrepancy monitoring ensures the Bypass Contactor closes
Over
temperature trip keeps track of heat sink temperature to
avoid SCR damage
Shunt
trip detects welded contactor or multiple shorted SCRs (when
used with shunt trip breaker)
Remaining
thermal capacity metering, to predict overloads
Metering of
A, B, C phase and ground fault currents The features of a protection relay at no additional cost!
Unique, Compact Design
- Narrow width for MCC (motor control center) mounting
- Integrated bypass contactor
- Low profile
for use in pump panels & other shallow enclosures
- Remote mount keypad capability
- Generous power terminal landing pads
- Pull apart control terminals for easy assembly & wiring
- Built-in features eliminate adding discreet devices
- Process control timers, metering, decel control, communications, and more
Remote Mount Keypad Option
Remotely mount the keypad and display up to 10 feet from the base unit, with
NEMA 1 or NEMA 4/12 bezels
Flexible Inputs & Outputs Put You in Control!
- Easy
access RS-485 comm port
with Modbus RTU protocol built-in, no add-on
communications module needed.
- Simple control wiring:
2 or 3 wire Start/Stop, N.C Interlock, PIC IE-Stop, Jog and Dual Ramp, all operated
at 24VDC for safety.
Dedicated fault triac
with opto-isolation for PLC interface
or connecting to an external relay.
- Emergency Bypass Input simple contact closure allows
for independent control of the Bypass contactor when emergency across-the-line
starting is needed. (For heavy duty applications requiring full voltage,
line start capability, see the VMX-HD Series).
- 3 dry contact relays:
2 FORM C and 1 FORM A, all fully programmable for over 30 functions including,
Run, At Speed, End of Decel, nine other status indicators and 13 trip indicators,
including an option to flash on certain faults.
Contact Joliet Technologies for pricing,
availability and freight options.
Phone: (815) 725-9696 or
Toll Free: (866) 492-9888
Fax: (815) 725-9393
E-mail: info@joliettech.com
RFQ - Request for Quote
|