Call Toll Free (866) 492-9888
|
Magnetek - Reduced Voltage Soft Starters
RVS-DN Digital Soft Starter
Joliet Technologies is now offering the Magnetek Line of
Soft Starters.
Magnetek Reduced Voltage Soft Starters
RVS-DN Digital Soft Start
Digital Soft Start 8-2700A, 200-600 Volts Heavy-Duty, Fully Featured
|
Advantages at a glance
- Standard Ratings: 8-2700A, 200-600V
- Optional Voltages: 380, 690 and 1000V
- Heavy duty, rated for 50°C
- Superior starting and stopping characteristics
- Comprehensive motor protection package
- User-friendly programming menu
- Operates off stand-by generator power
supply

8-72A
Performance Features
- Soft start and soft stop
- Current limit
- Pump control program
- Torque and current control for optimized
starting and stopping
- Jog with electronic reverse
- Pulse start for high break-away torque
- Linear acceleration (requires tach feedback)
- Four modes of fault reset
Protection Features
- Programmable maximum starts
- Stall detection
- Electronic shear pin (jam)
- Electronic overload with selectable curves
- Under current
- Phase loss and phase sequence
- Under and over voltage
- Load loss (motor not connected)
- Shorted SCR (Silicon Controlled Rectifier)
- Over-temperature

1100-1800A
LCD & LEDs Displays
- LCD-2 lines x 16 characters
- Selectable
languages:
English, German,
French and Spanish
- Two display modes
for basic and
advanced applications
- User friendly operation with default parameters
- Eight LEDs for quick operation status

Available Statistical Data
Data is stored in NV RAM,
and is retrievable via keypad
or serial communication
- Total run time
- Total number of starts
- Total number of trips
- Last start current
- Last start time
- Last trip
- Current at trip

|
Options
- Communication Protocal; RS-485, MODBUS,
PROFIBUS or MODBUS-TCP/IP
- Motor insulation test-monitors motor
insulation when motor is stopped, with
alarm and start inhibit set points

105-170A
- Analog output-related to motor's current;
selectable 0-20mA, 4-20mA and 0-10VDC
- Thermistor input, selectable as PTC or
NTC
- Preparation for Bypass-bus bar
arrangement to maintain protection when
bypass is closed
- Conformal coating for printed circuit boards
- Back-lit LCD
- Tach feedback card for synchronized
multi-motor starting

210-390A
Pump Control
Designed to prevent over-pressure during starting, and
water-hammer during stopping. Six field-adjustable starting
and stopping curves with adjustable final torque point.
Typical applications: Pumping to a high elevation or against
counter torque.
Jog with Electronic Reverse
Motor can be operated at 1/6 of rated speed for 30
seconds. Direction is reversed electronically, without contactors.
Typical applications: Positioning, maintenance and sewage
pumps-releasing jam conditions by reverse rotation.
Energy Saver
Supply voltage to the motor is reduced when motor is
lightly loaded. The RVS-DN lowers the rotating magnetic
field intensity, improving the power factor and reducing
power consumption.
Typical applications: Piston Compressors operating less than
50% of the duty cycle in less than 50% of their FLA current.
Auxiliary Relays
Programmable relays, 3 Form C, 8A, 220 VAC
- Immediate with adjustable on and off delays, can be
dedicated for shear-pin (jam) protection
- End of acceleration with adjustable "on" delay
- Fault, programmable as fault or fault fail-safe operation
- Low motor insulation alarm (optional)
Optional Communication Protocals
Optional Communication Protocols
- MODBUS-enables
setting, control and
supervision
- PROFIBUS DP-enabling
control and supervision
- MODBUS-TCP/IP-
supported according to
"Specification 1.0," via standard RJ45 computer
network connector (TBD)

Optional Analog Board
Two field programmable functions:
- Thermistor input, PTC or NTC
- Analog output, related to motor's current,
programmable as 0-10VDC, 4-20mA, 0-20mA
|
Optional Motor Insulation Tester
A unique feature for submersible pumps or motors
installed in humid and harsh environments, the
system measures motor insulation integrity when the
motor is not running. Two programmable levels are available:
- Alarm level, adjustable 0.2-5 MΩ
- Fault level, adjustable 0.2-5 MΩ, prevents starting when
insulation is below an acceptable level
|
|

|
Copyright © 2004
Information Provided by:
Magnetek ICG
N49 W13650 Campbell Drive
Menomonee Falls, WI 53051
Toll Free: 800-288-8178
Fax: 262-783-3510 |
Call Joliet Technologies TODAY
If you have any questions concerning Magnetek's line
of Soft Starters or related products, please contact us by:
Phone (815) 725-9696,
Toll Free (866) 492-9888,
Fax (815) 725-9393 or
E-mail info@joliettech.com
Joliet Technologies custom packages, integrates and engineers
AC Variable Frequency Drives (VFD), DC Variable
Speed Drives (VSD) and
AC Drive Controllers using top of the
line manufacturers, like ABB, Emerson-Control Techniques, Siemens, Fincor, Avtron and Magnetek. Our custom drive packages
are built to your specifications for your application. We specialize in large horsepower drives (500Hp and above). Call us at (815)
725-9696 or fax us at (815) 725-9393 or e-mail us or fill out an RFQ with your requirements.
|