ABB ACS550 AC DRIVES
0.75 HP (.55 kW) to 100 HP (75 kW) @ 208 to 240V
1.0 HP (.75 kW) to 550 HP (355 kW) @ 380 to 480V
ABB ACS550
AC DRIVES
ACS550 Features
Standard Features
- UL and cUL
- 1st Environment, Restricted Distribution CE Approval (30 m motor cable) for
R1 - R6 frames - 2nd Environment for R7 & R8 Frames
-
Start-Up Assistant
-
Full Graphic and Multilingual Display
-
Fused Disconnect (ACS550-U2 ONLY)
-
Two (2) Programmable Analog Inputs
-
Six (6) Programmable Digital inputs
-
Two (2) Analog Outputs
-
Adjustable Filters on Analog Inputs and Outputs
-
Input Speed Signals
-
Current 0 (4) ... 20 mA
- Voltage 0... 10VDC
- Increase/Decrease Reference Contacts
-
Fieldbus Adapters
-
Start/Stop
-
2 Wire (Dry Contact Closure)
-
3 Wire (Momentary Dry Contacts)
-
Adjustable Current Limit
-
Adjustable Torque Limit
-
Nine (9) Supervision Functions
-
Electronic Reverse
-
Motor ID Run
-
Power Loss Ride-Through
-
DC Injection Braking (in V/Hz ONLY)
-
DC Magnetizing Start
-
DC Hold
-
Flux Braking
-
Seven (7) Preset Speeds
-
Three (3) Critical Speed Lockout Bands
-
V/Hz, Sensorless and Flux Vector Modes of Motor Control (Flux vector not available at time of printing)
-
Automatic Reset Customer Selectable
-
Two (2) Independently Adjustable Accel and Decel Ramps
-
Linear or Two (2) Adjustable US" Curve Accel/Decel Ramps
-
Ramp or Coast to a Stop
-
Maximum Frequency Programmable up to 500 Hz
-
Two (2) Integral Independent Programmable PID Setpoint Controller
- Mathematical Functions on Analog Reference Signals
-
Patent Pending Swinging Choke Design for Harmonic Mitigation (R1 - R4 frames) 5% impedance
-
AC Input Line Reactor for Harmonic Mitigation (R5 - R8 frames) 3% impedance
-
Integral Brake Chopper (R1 & R2 Frames)
- Emergency Stop Ramp
- Modbus RTU
- Programmable Fault Functions for Protection include:
- AI<Min
-
Panel Loss
- External Fault
-
Motor Thermal Protection
-
Stall
-
Underload
-
Motor Phase Loss
-
Ground Fault
-
Preprogrammed Protections include:
-
Overcurrent
-
Short Circuit
-
Overvoltage
-
Undervoltage
-
Input Phase Loss
-
Output Device (IGBT) Overtemperature
-
Motor Overtemperature Protection Wt)
Available Options
-
3 Relay Extension Module OREL-01
-
115/230 V Digital Input Interface Module OHDI-01
-
Pulse Encoder Interface Module OTAC-01
-
Fieldbus Adapter Modules
-
DeviceNet RDNA-01
- Profibus-DP RPBA-01
-
Braking Units and Choppers
-
DriveWindow Light@-based Start-up, Operation, Programming and Diagnostic Tool
-
Fan Replacement Kits
-
Remote Panel Mounting Kit
-
Flange Mounting Kits
© 2004 ABB Inc. All rights reserved Specifications and pricing subject to change
without notice.
ACS550-US-03
Rev. E |
Effective: 3/1/04
Supersedes: 9/2/03 |
|