ABB ACS550 AC DRIVES
0.75 HP (.55 kW) to 100 HP (75 kW) @ 208 to 240V
1.0 HP (.75 kW) to 550 HP (355 kW) @ 380 to 480V
ABB
ACS550
AC DRIVES
380V Ratings
3-phase supply voltage 380, 400, 415, 440, 460 or 480 V - Power ratings are valid at
nominal voltage, 400 V (4, 5)
Type Code
UL Type 1
NEMA 1 (6,7,9) |
Nominal Ratings (4, 5) |
Frame
Size |
Price |
Normal Duty (VT)
(110% I2N) |
Heavy-duty (CT)
(150% I2hd) |
I 2N
A (1,3) |
P N
kW (8) |
I 2hd
A (2,3) |
P hd
kW (8) |
|
ACS550-U1-03A3-4 |
3.3 |
1.1 |
2.4 |
0.75 |
R1 |
CALL |
|
ACS550-U1-04A1-4 |
4.1 |
1.5 |
3.3 |
1.1 |
R1 |
CALL |
|
ACS550-U1-06A9-4 |
6.9 |
2.2 |
5.4 |
1.5 |
R1 |
CALL |
|
ACS550-U1-08A8-4 |
8.8 |
4 |
6.9 |
3 |
R1 |
CALL |
|
ACS550-U1-012A-4 |
11.9 |
5.5 |
8.8 |
4 |
R1 |
CALL |
|
ACS550-U1-015A-4 |
15.4 |
7.5 |
11.9 |
5.5 |
R2 |
CALL |
|
ACS550-U1-023A-4 |
23 |
11 |
15.4 |
7.5 |
R2 |
CALL |
|
ACS550-U1-031A-4 |
31 |
15 |
23 |
11 |
R3 |
CALL |
|
ACS550-U1-038A-4 |
38 |
18.5 |
31 |
15 |
R3 |
CALL |
|
ACS550-U1-044A-4 |
44 |
22 |
38 |
18.5 |
R4 |
CALL |
|
ACS550-U1-059A-4 |
59 |
30 |
44 |
22 |
R4 |
CALL |
|
ACS550-U1-072A-4 |
72 |
37 |
59 |
30 |
R4 |
CALL |
|
ACS550-U1-077A-4 |
77 |
41 |
65 |
37 |
R5 |
CALL |
|
ACS550-U1-096A-4 |
96 |
45 |
77 |
41 |
R5 |
CALL |
|
ACS550-U1-124A-4 |
124 |
55 |
96 |
45 |
R6 |
CALL |
|
ACS550-U1-157A-4 |
157 |
75 |
124 |
55 |
R6 |
CALL |
|
ACS550-U1-180A-4 |
180 |
90 |
156 |
75 |
R6 |
CALL |
|
ACS550-02-245A-4 |
245 |
132 |
192 |
110 |
R7 |
CALL |
|
ACS550-02-368A-4 |
368 |
200 |
284 |
160 |
R8 |
CALL |
|
ACS550-02-486A-4 |
486 |
250 |
414 |
225 |
R8 |
CALL |
|
ACS550-02-526A-4 |
526 |
280 |
477 |
250 |
R8 |
CALL |
|
ACS550-02-602A-4 |
602 |
315 |
515 |
280 |
R8 |
CALL |
|
ACS550-02-645A-4 |
645 |
355 |
590 |
315 |
R8 |
CALL |
|
ACS550-U2-196A-4 |
196 |
110 |
162 |
90 |
R7 |
CALL |
|
ACS550-U2-245A-4 |
245 |
132 |
192 |
110 |
R7 |
CALL |
| ACS550-U2-316A-4 |
316 |
160 |
240 |
1321 |
R8 |
CALL |
|
ACS550-U2-368A-4 |
368 |
200 |
302 |
160 |
R8 |
CALL |
|
ACS550-U2-414A-4 |
414 |
225 |
368 |
200 |
R8 |
CALL |
|
ACS550-U2-486A-4 |
486 |
250 |
414 |
225 |
R8 |
CALL |
|
ACS550-U2-526A-4 |
526 |
280 |
477 |
250 |
R8 |
CALL |
|
ACS550-U2-602A-4 |
602 |
315 |
515 |
280 |
R8 |
CALL |
|
ACS550-U2-545A-4 |
645 |
355 |
590 |
315 |
R8 |
CALL |
|
Note: All drives are supplied w/Advanced Control Panel. |
|
(Call Joliet Technologies for
prices) |
NOTES
- I2N: continuous base current with 110% overload for 1 minute /10 minutes.
- 12hd: continuous base current with 150% overload for 1 minute /10 minutes.
- 180% Ihd continuous base current available for 2 seconds /1 minute.
- Current ratings do not change with different supply voltages.
- The rated current of the ACS550 must be greater than or equal to the rated
motor current to achieve the rated motor power given in the table.
- All-U1 models -03A3 through -180A come with a conduit box and advanced control panel as standard.
- All -U2 models come standard with US conduit plate. top entry / top exit,
common mode filter for R8 drives, fused disconnect and extended enclosure
with advanced control panel.
- Kilowatts are based on IEC motor ratings for most 4 and 6-pole motors (1500,1000 rpm). Check motor nameplate current for compatibility.
- All -02 models come standard with blank conduit plate. bottom entry/exit.
common mode filter for R8 drives and advanced control panel.
© 2004 ABB Inc. All rights reserved Specifications and pricing subject to change
without notice.
ACS550-US-O3
Rev. F |
Effective: 5/13/04
Supersedes: 3/1/04 |
|